EV Battery Pack Cell Equalizer (24 Channels)
ELB300 is designed for new energy batteries such as lithium iron phosphate, ternary lithium and lithium manganate, and can quickly solve the cruising range degradation caused by the difference in cell capacity due to inconsistent cell voltages.
Features
1. The 7-inch LCD touch screen and the intuitive menu simplified the operation.
2. Portable, easy to carry and transport.
3. Applied to all common lithium battery packs testing with various voltage levels.
4. Equalizing maintenance test mode can activate the lithium battery performance completely.
5. Support intelligent equalizing function, and equalizing maintenance parameter customization.
6. Adopt wave width modulation technology, high efficiency, high power factor, low noise, and low electromagnetic interference.
7. Support multiple protection design and alarm settings of voltage, current, temperature abnormal to protect the battery and the balancer.
8. Support the safety protection functions such as overvoltage, undervoltage, overcurrent, output short circuit, anti-reverse protection and overheating protection.
9. Multiple discharge auto-stop conditions make testing mode more intelligent and flexible, and avoid over-charge and over-discharge.
Specifications
Display 7'' capacitive LCD touch screen, 800*480 Power Input Single phase AC 90~264V, 40~60Hz Charging & Discharging Voltage Range DC 1.8~4.2V Voltage Measurement Accuracy ±0.1%FS±2mV(maximum range 5V) Charging & Discharging Current Range 0.1~5A(Max) Current Measurement Accuracy ±0.1%FS±0.05mV(maximum range 5A) Battery Temperature Detection Accuracy ±2℃(-25~+85℃) Charge and discharge temperature range can be set
The Number of Channels 2*12 Charging & Discharging Power 600W Max Battery Interface 16Pin, 24Pin PC Data Communication TCP/IP, USB-Device Wireless Communication WIFI and BT(WIFI external antenna) Charging Mode Constant current charging + constant voltage charging Discharging Mode Constant current(constant power, constant resistance discharge can be set) Protection Function Input overcurrent protection, overvoltage protection, output overcurrent protection, overtemperature protection SAFETY TEST
Breaking Down Test AC input-case: 2200Vdc 1 min AC input-case DC input-output: 2200Vdc 1 min DC input-case WORKING ENVIRONMENT
Radiation Method Forced air cooling Temperature Working temperature range: -5~40℃
Storage temperature: -20~70℃
Humidity Relative humidity 0~90%(40±20℃) Elevation Rated altitude 2000m SIZE AND WEIGHT
Dimensions/Weight 380*275*460(mm)/17kg